Page 80 MEAN WELL LED DRIVER CATALOG
P. 80








series 30~60W



Features
• Constant current mode • Protections: Short circuit / Over current / Over voltage
• Universal AC input / Full range • Cooling by free air convection
• Class 2 power unit / Pass LPS • 2 years warranty
• Suitable for built-in LED lighting systems


PLP-30 PLP-45/60









AC input voltage range 90~264VAC; 127~370VDC
PLP-45: Cold start, 30A at 230VAC
AC inrush current (max.) Cold start, 25A at 230VAC
PLP-60: Cold start, 35A at 230VAC
Current adjustment range 75%~100%
Over Range 100%~110%
current
protection Type Constant current limiting, auto-recovery
Setup time 500ms at full load and 230VAC
Withstand voltage I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC
O
Working temperature -30~+70 C (refer to "OUTPUT LOAD vs TEMPERATURE")
Safety standards UL8750, TUV BS EN61347-1, BS EN61347-2-13, EAC TP TC 004 approved
BS EN55015, BS EN61000-3-2 class C, BS EN61000-3-3, BS EN61000-4-2,3,4,5,6,8,11,
EMC standards
BS EN61547, EAC TP TC 020
Connection 3+2P / 3.96mm pitch, JST P/N: B3P / B2P-VH
Dimension (LxWxH)(mm) 101.6x 50.8x 26.6 101.6x 50.8x 29.6

(for 48V only) (for 12/24V)
PLP-30 Series
Model No. Output Tol. R&N Effi. Model No. Output Tol. R&N Effi.
PLP-30-12 12V, 0~2.5A ±10% 2.0V 83.0% PLP-45-24 24V, 0~1.9A ±10% 3.8V 89%
PLP-45-48 48V, 0~0.95A ±10% 4.8V 89%
PLP-30-24 24V, 0~1.3A ±10% 2.4V 85.5%
PLP-30-48 48V, 0~0.63A ±10% 4.8V 86.5% (for 48V only) (for 12/24V)
PLP-60 Series
(for 48V only) (for 12/24V) Model No. Output Tol. R&N Effi.
PLP-45 Series PLP-60-12 12V, 0~5.0A ±10% 4.5V 84%
Model No. Output Tol. R&N Effi. PLP-60-24 24V, 0~2.5A ±10% 4.5V 88%
PLP-45-12 12V, 0~3.8A ±10% 4.2V 86% PLP-60-48 48V, 0~1.3A ±10% 4.8V 89%


Special Symbols for EN61347-2-13

110 Protection against overheating to prevent the lamp controlgear case temperature under any conditions of use from
O
exceeding the indicated value (110 C)
F Suitable for direct mounting on normally flammable surfaces, such as wood (>2mm)
M M Based on VDE0710-14, can be installed inside a wooden material like wooden cabinet.
The minimum distance between the product enclosure to wooden material in each side is defined.
LPS Limited power source
o
tc: 80 C O O
o
ta: 40 C Full load operation up to 40 C with surface temperature of case < 80 C
SELV Vo< 120VDC can have this mark on the unit, also design with isolation between primary and secondary